Error while Accessing Sectona PAM URL

Issue

You may encounter a Runtime Error instead of the login page when accessing the Sectona PAM URL through a browser.

Error: “Server Error in '/' Application. Runtime Error”

The page displays the message: “An exception occurred while processing your request. Additionally, another exception occurred while executing the custom error page for the first exception. The request has been terminated.”

image-20261118-105335.png

Cause

This issue occurs when the required .NET Framework prerequisites for Sectona PAM are missing from the application server, preventing the web application from running. This commonly occurs after upgrading the server operating system from Windows Server 2016 to Windows Server 2019.

Resolution

Install the .NET Framework prerequisites provided by the Sectona Team and restart the PAM application server.

  • Log in to the PAM application server.

  • Install the required .NET Framework prerequisites.

  • Restart the server after the installation is complete.

  • Once the server is back online, access the PAM URL again and verify that the login page loads without the runtime error.