Issue
The WMon service is running, but port “8389” (0.0.0.0:8389) is not in a listening state. The following error is observed in the WMon logs.
Error:
Log Source: WMonMain.HostService
Data: A TCP error (10106: The requested service provider could not be loaded or initialized)
occurred while listening on IP Endpoint=0.0.0.0:8389
Type: Error
Cause
-
Winsock catalog corruption on the server.
-
A third-party LSP (Layered Service Provider) entry injected by antivirus or endpoint security software prevents the WMon service from binding to port “8389”.
-
Another process is already occupying port “8389”.
-
Firewall restrictions are preventing the WMon service from binding to the port.
Resolution
-
Open Command Prompt as Administrator and run the following command to reset the Winsock catalog:
“netsh winsock reset”
-
Restart the server by running:
“shutdown /r /t 0”
-
After the server restarts, verify that port “8389” is in the LISTENING state by running:
netstat -ano | findstr "8389"
-
Verify that the WMon service is running correctly and that logs are being captured as expected.
To prevent the issue from recurring, whitelist the Sectona/WMon installation folder and port “8389” in your antivirus or endpoint security software.